|

|


|


|


|
5 Slot Full Mesh VPX Backplane 5 Slot full mesh VPX backplane Slots: 5 Justification: N/A
|
Custom aTCA All aTCA Topologies Available Slots: 2, 6, 14 64-Bit: YES Topology: All
|
Custom cPCI CompactPCI Slots: 2 - 21 Justification: Right, Left, or Center Volts: 3.3V / 5V Options: H.110 64-Bit: YES
|
DS14 Dual Star Backplane Slots: 14 64-Bit: YES Topology: Dual Star
|
  

|
Call 1.800.926.8722 for a Quote
|
|
5 Slot Full Mesh VPX Backplane

Specifications

Description: 5 Slot full mesh VPX backplane Slots: 5 Justification: N/A
|

|


|

Call 1.800.926.8722 for a Quote
|
|
Custom aTCA

Topologies: - Full Mesh
- Dual Star
Two to 16 slots customizable - Backplanes for all topologies
- Two, six, and 14 slot backplanes available
Specifications

Description: All aTCA Topologies Available Slots: 2, 6, 14 64-Bit: YES Topology: All
|

|


|

Call 1.800.926.8722 for a Quote
|
|
Custom cPCI

- Two to 21 Slots Custom
- 6U or 7U Format
- 64 Bit Operation
- 5 V/3.3 V Supported
- CT Bussing (ECTF H.110)
- Hot Swap Compatible
- ATX Power Supply Connectors
- Bridgeable with Center CPU
- IPMI Supported
Specifications

Description: CompactPCI Slots: 2 - 21 Justification: Right, Left, or Center Volts: 3.3V / 5V Options: H.110 64-Bit: YES
|

|


|

Call 1.800.926.8722 for a Quote
|
|
DS14

- Backplane topologies:
- 2 to 16 slots customizable
- Backplanes for all topologies
- 2, 6, and 14 slot backplanes available now
Specifications

Description: Dual Star Backplane Slots: 14 64-Bit: YES Topology: Dual Star
|

|


|


|


|

|
FB Series
|
FM02 Full Mesh Backplane Slots: 2 64-Bit: YES Topology: Full Mesh
|
FM06 Full Mesh Backplane Slots: 6 64-Bit: YES Topology: Full Mesh
|
Full Mesh aTCA Backplanes Full mesh backplanes Slots: 2, 5, 6, 14 Topology: Full mesh
|


|

Call 1.800.926.8722 for a Quote
|
|
FB Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- Superior power distribution
- Unique signal routing minimizes crosstalk
- 100% press-ft construction for reliability
- Option codes specify shrouds or automatic bus grant jumper feature
- Bus bar kits available
- Fully supports J1 requirements of ANSI/VITA-1 1994 VME64
|

|


|

Call 1.800.926.8722 for a Quote
|
|
FM02

- Backplane topologies:
- 2 to 16 slots customizable
- Backplanes for all topologies
- 2, 6, and 14 slot backplanes available now
Specifications

Description: Full Mesh Backplane Slots: 2 64-Bit: YES Topology: Full Mesh
|

|


|

Call 1.800.926.8722 for a Quote
|
|
FM06

- Backplane topologies:
- 2 to 16 slots customizable
- Backplanes for all topologies
- 2, 6, and 14 slot backplanes available now
Specifications

Description: Full Mesh Backplane Slots: 6 64-Bit: YES Topology: Full Mesh
|

|


|
Call 1.800.926.8722 for a Quote
|
|
Full Mesh aTCA Backplanes

Specifications

Description: Full mesh backplanes Slots: 2, 5, 6, 14 Topology: Full mesh
|

|


|


|


|


|
LA Series VME64 J1 Slots: 3 - 21 64-Bit: YES Power Distribution: Standard
|
LC Series VME64 J1 Slots: 3 - 21 Options: ABG 64-Bit: YES Power Distribution: Standard
|
LD Series VME64 J1 Slots: 3 - 21 Options: Shrouds, ABG 64-Bit: YES Power Distribution: Standard
|
LF Series VME64 J1/J2 Slots: 3 - 21 64-Bit: YES Power Distribution: Standard
|
  

|

Call 1.800.926.8722 for a Quote
|
|
LA Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- Superior power distribution
- Unique signal routing minimizes crosstalk
- 100% press-ft construction for reliability
- Option codes specify shrouds or automatic bus grant jumper feature
- Bus bar kits available
- Fully supports J1 requirements of ANSI/VITA-1 1994 VME64
Specifications

Description: VME64 J1 Slots: 3 - 21 64-Bit: YES Power Distribution: Standard
|

|
  

|

Call 1.800.926.8722 for a Quote
|
|
LC Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- Superior power distribution
- Unique signal routing minimizes crosstalk
- 100% press-ft construction for reliability
- Option codes specify shrouds or automatic bus grant jumper feature
- Bus bar kits available
- Fully supports J1 requirements of ANSI/VITA-1 1994 VME64
Specifications

Description: VME64 J1 Slots: 3 - 21 Options: ABG 64-Bit: YES Power Distribution: Standard
|

|
  

|

Call 1.800.926.8722 for a Quote
|
|
LD Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- Superior power distribution
- Unique signal routing minimizes crosstalk
- 100% press-ft construction for reliability
- Option codes specify shrouds or automatic bus grant jumper feature
- Bus bar kits available
- Fully supports J1 requirements of ANSI/VITA-1 1994 VME64
Specifications

Description: VME64 J1 Slots: 3 - 21 Options: Shrouds, ABG 64-Bit: YES Power Distribution: Standard
|

|


|

Call 1.800.926.8722 for a Quote
|
|
LF Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- SIE's proprietary patented trace routing for normalized decoupling of adjacent signal, data, and control lines reduces crosstalk while maintaining the controlled transmission line impedance and short propagation delay required by VME64
- Common power planes for +5V and GND across J1 and J2 eliminate ground loops
- Matched impedance of J1 and J2
- 100% press-ft construction for reliability
- All signal pins accessible from both sides of the backplane
- Bus bar kits available
Specifications

Description: VME64 J1/J2 Slots: 3 - 21 64-Bit: YES Power Distribution: Standard
|

|


|


|


|


|
LG Series VME64 J1/J2 Slots: 3 - 21 Options: Shrouds 64-Bit: YES Power Distribution: Standard
|
LK Series VME64 J1/J2 Slots: 3 - 21 Options: ABG 64-Bit: YES Power Distribution: Standard
|
LL Series VME64 J1/J2 Slots: 3 - 21 Options: Shrouds, ABG 64-Bit: YES Power Distribution: Standard
|
LN Series VME64 J1/J2 Slots: 3 - 21 Options: Shrouds, Bus Bars 64-Bit: YES Power Distribution: Standard
|


|

Call 1.800.926.8722 for a Quote
|
|
LG Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- SIE's proprietary patented trace routing for normalized decoupling of adjacent signal, data, and control lines reduces crosstalk while maintaining the controlled transmission line impedance and short propagation delay required by VME64
- Common power planes for +5V and GND across J1 and J2 eliminate ground loops
- Matched impedance of J1 and J2
- 100% press-ft construction for reliability
- All signal pins accessible from both sides of the backplane
- Bus bar kits available
Specifications

Description: VME64 J1/J2 Slots: 3 - 21 Options: Shrouds 64-Bit: YES Power Distribution: Standard
|

|


|

Call 1.800.926.8722 for a Quote
|
|
LK Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- SIE's proprietary patented trace routing for normalized decoupling of adjacent signal, data, and control lines reduces crosstalk while maintaining the controlled transmission line impedance and short propagation delay required by VME64
- Common power planes for +5V and GND across J1 and J2 eliminate ground loops
- Matched impedance of J1 and J2
- 100% press-ft construction for reliability
- All signal pins accessible from both sides of the backplane
- Bus bar kits available
Specifications

Description: VME64 J1/J2 Slots: 3 - 21 Options: ABG 64-Bit: YES Power Distribution: Standard
|

|


|

Call 1.800.926.8722 for a Quote
|
|
LL Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- SIE's proprietary patented trace routing for normalized decoupling of adjacent signal, data, and control lines reduces crosstalk while maintaining the controlled transmission line impedance and short propagation delay required by VME64
- Common power planes for +5V and GND across J1 and J2 eliminate ground loops
- Matched impedance of J1 and J2
- 100% press-ft construction for reliability
- All signal pins accessible from both sides of the backplane
- Bus bar kits available
Specifications

Description: VME64 J1/J2 Slots: 3 - 21 Options: Shrouds, ABG 64-Bit: YES Power Distribution: Standard
|

|


|

Call 1.800.926.8722 for a Quote
|
|
LN Series

- Optimized performance for cost-effective six layer design
- 100% Level 3 electrical testing
- SIE's proprietary patented trace routing for normalized decoupling of adjacent signal, data, and control lines reduces crosstalk while maintaining the controlled transmission line impedance and short propagation delay required by VME64
- Common power planes for +5V and GND across J1 and J2 eliminate ground loops
- Matched impedance of J1 and J2
- 100% press-ft construction for reliability
- All signal pins accessible from both sides of the backplane
- Bus bar kits available
Specifications

Description: VME64 J1/J2 Slots: 3 - 21 Options: Shrouds, Bus Bars 64-Bit: YES Power Distribution: Standard
|

|